Welcome to Top Store

Kestrel 5000AG Livestock Environmental Meter

Rugged and accurate, this meter measures wind/air speed, temperature, humidity, THI, and airflow and is ideal for livestock and crop production, research, education, ventilation, and facility design. In addition, it has onboard data logging and graphing and displays over ten parameters on a large, high-resolution display

  • Kestrel 5000AG Offers

    Compact, lightweight, and multi-functional, this environmental meter meets the needs of livestock, agriculture, and animal health professionals. Use this meter inside and out for spot measurements, and track and log over 10,000 sets of time-stamped data. Moreover, producers, growers, veterinarians, and consultants in every field of agriculture will gain vital information regarding micro-climate conditions needed to maximize performance and profitability.

    Features

    • Measures wind speed/air speed, temperature, humidity, THI, air flow and displays over 10 total environmental parameters on large, hi-res, hi-contrast, graphic display
    • Handheld, portable environmental meter with onboard data logging and graphing
    • Rugged (drop tested to MIL-STD-810G standards), waterproof and dustproof (sealed to IP67 standards)
    • Backlight – switchable white/red
    • Battery life indicator
    • Data log graph view
    • Data logging – adjustable interval
    • Date and time
    • High contrast, sunlight readable monochrome LCD
    • Integrated flip open impeller cover
    • Intuitive tactile up/down/enter keypad
    • Multilingual menus (English, French, Spanish, and German)
    • Minimum/maximum/average reading
    • Pressure, relative humidity, and temperature sensors
    • THI warning flag – settable

    Applications

    • Livestock and crop production
    • Research
    • Education
    • Ventilation
    • Facility design

Spesifikasi

Kestrel 5000AG Specifications

Sensors
Wind/Air SpeedRange:
0.6 to 40 m/s
118 to 7874 ft/min
2.2 to 144 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots

Accuracy:
Larger of 3% of reading, least significant digit or 20 ft/min speed

Resolution:
0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots

Ambient TemperatureRange: -20 to 158°F (-29 to 70°C)
Accuracy: 0.9°F (0.5°C)
Resolution: 0.1°F/C
Relative HumidityRange: 10 to 90% (25°C) non-condensing
Accuracy: 2% RH
Resolution: 0.1% RH
PressureRange: 77°F/25°C, 700 to 1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 psi
Accuracy: 1.5 hPa|mbar, 0.044 inHg, 0.022 psi
Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 psi
Calculated Measurements
AltitudeAccuracy (±): 23.6 ft/7.2 m from 750 to 1100 mBar (typical), 48.2 ft/14.7 m from 300 to 750 mBar (maximum)
Resolution: 1 ft/1 m
Sensors employed: Pressure, User Input (Reference Pressure)
Air FlowAccuracy (±): 6.71%
Resolution: 1 cfm, 1 m3/hr, 1 m3/m, 0.1 m3/s, 1 L/s
Sensors employed: Air Speed, User Input (duct shape and size)
Barometric PressureAccuracy (±): 0.07 inHg, 2.4 hPa|mbar, 0.03 psi
Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 psi
Sensors employed: Pressure, User Input (Reference Altitude)
Density AltitudeAccuracy (±): 226 ft/69 m
Resolution: 1 ft/1 m
Sensors employed: Temperature, Relative Humidity Pressure
Dew PointAccuracy (±): 3.4°F/1.9°C, 15 to 95% RH*
Resolution: 0.1°F/C
Sensors employed: Temperature, Relative Humidity
*Refer to Range for Temperature Sensor
Heat IndexAccuracy (±): 7.1°F/4°C
Resolution: 0.1°F/C
Sensors employed: Temperature, Relative Humidity
THINRC
Accuracy (±): 1.5°F/0.8°C
Resolution: 0.1°F/C
Sensors employed: Temperature, Relative Humidity

Yousef
Accuracy (±): 2.3°F/1.3°C
Resolution: 0.1°F/C
Sensors employed: Temperature, Relative Humidity

Wet Bulb Temperature
(Psychrometric)
Accuracy (±): 3.2°F/1.8°C
Resolution: 0.1°F/C
Sensors employed: Temperature, Relative Humidity Pressure
Wind ChillAccuracy (±): 1.6°F/0.9°C
Resolution: 0.1°F/C
Sensors employed: Wind Speed, Temperature
General Specifications
Display and BacklightMultifunction, multidigit monochrome dot-matrix display
Choice of white or red LED backlight
Response Time and
Display Update
Display updates every 1 second
After exposure to large environmental changes, sensors require an equilibration period to reach stated accuracy
Measurements employing RH may require longer periods, particularly after prolonged exposure to very high/low humidity
Data Storage and
Graphical Display
Minimum/Maximum/Average
History
Logged history stored and displayed for every measured value
Manual and auto data storage
Minimum/Maximum/Average history may be reset independently
Auto-store interval settable from 2 seconds to 12 hours, overwrite on or off
Logs even when displaying off except for 2 and 5-second intervals
Holds over 10,000 data points
CertificationsCE certified, RoHS, FCC, IC tested and WEEE compliant
Shock ResistanceMIL-STD-810g, Transit Shock, Method 516.6 Procedure IV
SealingWaterproof (IP67 and NEMA-6)
Battery LifeUp to 400 hours of use, reduced by backlight, alert light and buzzer
Display and Battery
Operational Temperature
Limits
14 to 131°F (-10 to 55°C)
Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading
Storage Temperature-22 to 140°F (-30 to 60°C)
Dimensions5 x 1.9 x 1.1″ (12.7 x 4.5 x 2.8 cm)
Weight4.3 oz (121 g) including battery

Ulasan

Belum ada ulasan.

Hanya pelanggan yang sudah login dan telah membeli produk ini yang dapat memberikan ulasan.

SKU: Kestrel 5000-1-1 Kategori: Tag: Brand:

Cart

Your Cart is Empty

Back To Shop
Continue Shopping
Payment Details
Sub Total Rp0