Category
- Uncategorized
- Accessories GPS Geodetik
- Accessories Lain
- Accessories Survey
- Alat Curah Hujan
- Anemometer
- Anemometer Kestrel
- Automatic Digital Level
- Automatic Level
- Borescope Endoscope
- Bushnell H2O
- Bushnell Lainnya
- Bushnell Powerview
- Bushnell Powerview 2
- Detektor Petir
- Digipas Digital Level
- Drone
- Dulang
- Echo Sounder
- Global Water
- GPS Furuno
- GPS Garmin
- GPS Geodetik
- GPS Trimble
- Hammer Test & Profometer
- Hardness Tester
- Humidity / Temp
- Kabel Locator
- Kaca Pembesar / Loupe
- Kamera Trap
- Kompas & Altimeter
- Laser level / Crossline Laser
- Leica Disto Meter
- LiDAR Laser Scanner
- Meteran
- Nikon Action EX
- Nikon Aculon
- Nikon Monarch
- Palu Geologi
- Photometer
- Planimeter
- Radar Gun
- Rangefinder
- Rite in the Rain
- Rotating Laser level
- Sampel Bags Kain Plastik
- Software
- Spotting Scopes
- Tachometer
- Telepon Satelit
- Tension Meter
- Teropong Malam/Night Vision
- Teropong Marine
- Theodolite & Laser Plummet
- Total Station
- Total Station Robotic
- USV
- Water Level Meters
- Weather Station
Hanna HI83306 Environmental Analysis Photometer
- Advanced optical system
- Unparalleled performance from a benchtop photometer
- Digital pH electrode input
- Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter
- Absorbance measuring mode
Features and Benefits
Digital pH Electrode Input
- Measure pH and temperature with a single probe
- Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
- pH CAL CheckTM alerts user to potential problems during the calibration process
- Space saving having a pH meter and photometer built into one meter
Data Logging
- Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button
- Sample ID and User ID information can be added to a logged reading using alphanumeric keypad
Connectivity
- Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
- Data is exported as a .CSV file for use with common spreadsheet programs
Battery Status Indicator
- Indicates the amount of battery life left
Error Messages
- Photometric error messages include no cap, high zero, and standard too low
- pH calibration messages include clean electrode, check buffer and check probe
Backlit 128 x 64 Pixel Graphic LCD Display
- Backlit graphic display allows for easy viewing in low light conditions
- The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter
Built-in Reaction Timer for Photometric Measurements
- The measurement is taken after the countdown timer expires.
- Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements
Absorbance mode
- Hanna’s exclusive CAL CheckTM cuvettes for validation of light source and detector
- Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry
Units of Measure
- Appropriate unit of measure along with chemical form is displayed along with reading
Result Conversion
- Automatically convert readings to other chemical forms with the touch of a button
Cuvette Cover
- Aids in preventing stray light from affecting measurements
On-Screen Features
Method Selection Users can easily select any one of the 23 measurement methods via the dedicated METHOD button.
Data Logging Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use.
pH Measurement Mode Selecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.Specifications
| Specification | Detail |
|---|---|
| sku | HI83306-01 |
| Wavelength Accuracy | ±1 nm |
| Light Source | 4 LEDs with 420 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters |
| Spectral bandwidth | 8 nm |
| Input Channels | 1 pH electrode input and 5 photometer wavelengths |
| pH Electrode | digital pH electrode (not included) |
| Logging Type | log on demand with user name and sample ID optional input |
| Logging Memory | 1000 readings |
| Connectivity | USB-A host for flash drive micro-USB-B for power and computer connectivity |
| GLP | calibration data for connected pH electrode |
| Display | 128 x 64 pixel LCD with backlight |
| Battery Type / Life | 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement |
| Power Supply | 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) |
| Environment | 0 to 50.0oC (32 to 122.0oF) 0 to 95% RH, non-condensing |
| Dimensions | 206 x 177 x 97 mm (8.1 x 7.0 x 3.8) |
| Weight | 1.0 kg (2.2 lbs.) |
| Photometer/Colorimeter Light Detector | silicon photodetector |
| Cuvette Type | round, 24.6 mm |
| Number of Methods | 128 max. |
| Ordering Information | Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. |
| Warranty | 2 years |
| Note | *Reagents are not included. |
Hanya pelanggan yang sudah login dan telah membeli produk ini yang dapat memberikan ulasan.
SKU: HI83306 Kategori: Photometer Tag: Hanna HI83306, Hanna HI83306 Environmental Analysis Photometer, Hanna HI83306 Photometer Brand: Hanna
Invoice & Faktur Pajak

Dexsa Utama akan menerbitkan Kwitansi, Invoice, Faktur Pajak , Surat Jalan dan dikirimkan bersama Barang Pesanan.
Transaksi 100% Aman

Dexsa Utama menghadirkan pilihan metode pembayaran yang aman dan nyaman Melalui Rekening Perusahaan
Garansi & Jaminan Keaslian

Dexsa Utama menjamin produk yang kami jual 100% original berkualitas & Bergaransi




Ulasan
Belum ada ulasan.