Mitech MH600 Leeb Hardness Tester

Harga Sudah termasuk PPN 10%

  • Based on the principle of Leeb hardness testing principle. It can measure the Leeb hardness of all metallic materials.
  • One main unit can match to 5 impact devices automatically identify the type without calibration.
  • Automatically identify the state of impact devices (connect, disconnect, error, etc)
  • Automatically identify the direction of impact device (except G), 360˚ comprehensive free measurement.
  • 320 x 240 TFT LCD screen, information-rich intuitive, clear display, adjustable brightness, easy to use dimly lit environment and intense sunlight.
  • Basic (single-point) calibration and multi-point calibration function for convert curve to reduce the test error.
  • Hardness scales can be converted to HL, HRB, HRA, HV, HS.
  • Built-in Leeb hardness conversion function to converse HLD to HLC, HLG, HLDL, HLD+15 which is convenient for calibration and value conversion.
  • Preset up and low limit of hardness value, it will alarm automatically if out of range alarm, convenient for batch testings.
  • Chinese-English converting, menu operation, easy and convenient.
  • It can store 500 groups (impact times 32 – 1) hardness values, each data includes single testing value, average value, measurement date/time, impact direction, frequency, material, hardness and other information.
  • Two ordinary AA batteries, it can work for not less than 100 hours, automatically screen standby, automatic sleep, automatic shutdown and other power-saving features.
  • USB interface can do transmission measurements, value storage management, value statistical, printing the value report and batch setting the instrument parameters through the PC data-pro software, to meet the highher demand for quality assurance and management.
  • ABS plastic seal design, IP65 protection, which can effectively prevent oil, dust and other corrosion of harsh environments.
  • Dimension 150mm x 76mm x 38mm.
Berat6 kg

Specifications

Technical Specifications

Technical Specifications

Technical Parameters

Measuring Range

(170 – 960) HLD

Error and Repeatability

Impact device D 760±30HLD,±6HLD

530±40HLD,±10HLD

Impact device DC 760±30HLDC,±6HLDC

530±40HLDC,±10HLDC

Impact device DC 736±40HLDL,±12HLDL

878±30HLDL,±12HLDL

Impact device D+15 766±30HLD+15,±12HLD+15

544±40HLD+15,±12HLD+15

Impact device G 590±40HLG,±12HLG

500±40HLG,±12HLG

Impact device C 822±30HLC,±12HLC

590±40HLC,±12HLC

Impact Direction

Vertically downward, oblique, horizontal, oblique, vertical upward, automatically identify

Material

Steel and cast steel, Cold work tool steel, Stainless steel, Grey cast iron, Nodular cast iron, Cast aluminum alloys, BRASS (copper-zinc alloys), BRONZE (cooper-aluminum/tin alloys), Wrought copper alloys

Hardness Scale

HL, HB, HRB, HRC, HRA, HV, HS

Display

Color TFT, 320 x 240 dots, dot-matric LCD

Built-in

Conversion table from(to) HLD to(from) HLC, HLG, HLDL, HLD+15

Integrated Data Memory

500 measurement series (Relative to average times 32 – 1)

Battery

3V, two AA size, alkaline batteries

Standby Time

About 100 hours (with default brightness)

Communication Interface

USB 1.1

Features

Application Fields

  • Die cavity of molds.
  • Bearings and other parts.
  • Failure analysis of pressure vessel, steam generator and other equipment.
  • Heavy work piece.
  • The installed machinery and permanently assembled parts.
  • Testing surface of a small hollow.
  • Requirements of formal original record for test results.
  • Material identification in the warehouse of metallic materials.
  • Rapid testing in large range and multi-measuring areas for large-scale work piece.

 

Application Conditions

  • Surface temperature can’t be overheat, less than 120˚C
  • Surface roughness should not be too large, otherwise it will cause errors. The surface of the work piece must be exposed metallic luster, smoothing and polish, without oil.
  • The specimens with 2-5kg or thin-walled specimens overhangs should be supported with some object in order to avoid the specimen deformation, bending and movement cause by impact, for medium-sized work piece, it shall be placed on flat and hard surface, the sample must be placed absolutely smoothly, without any shake, for heavy samples more than 5kg, it can be measured directly without any support.
  • Portable Leeb hardness tester has stict requirements for sample thickness, the minimum thickness shall comply with regulatory (see instructions).
  • For work piece with hardenend layer on surface, the depth of hardened layer should conform to regulatory.
  • For lighter parts, please make it tighly coupled with support, two coupled surface must be flat and smooth, the coupling gel should not be too much, the direction of the test shall be perpendicular to the coupling plate, if the work piece is a large plate, pole or bending material, even if the weight and thickness is ok, it may still cause deformation and instability resulting in test values error, it should be reinforced or supported at the back of the test points.
  • Magnetic of work piece should be less than 30 gauss.
  • For artifact surface : The work piece surface is preferably flat. When the curvated radius R of measured surface is less than 30mm, the work pieces should be tested with the small support ring or the shaped support rings.

 

Working Conditions

  • Working temperature : -10˚C – 50˚C
  • Storage temperature : -30˚C – 60˚C
  • Relative humidity : ≤90%
  • The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

 

Impact Devices

  • D : Stand configuration, for normal testing
  • D C : Test hole or hollow cylindrical
  • D L : Test slender narrow groove or hole
  • D+15 : Test groove or concave surface
  • G : Test large thick heavy and rough surface steel
  • C : Test small, light thin parts and surface of hardened layer

Include

  1. Main Unit (Quantity 1)
  2. D type impact device (Quantity 1)
  3. Standard test block (Quantity 1)
  4. Cleaning brush (A) (Quantity 1)
  5. Small support ring (Quantity 1)
  6. AA size Alkaline battery (Quantity 2)
  7. Manual (Quantity 1)
  8. ABS instrument package case (Quantity 1)
  9. Data-pro software (Quantity 1) On PC
  10. Communication cable (Quantity 1) Mini USB-B to USB-A
  11. Screw driver

Brosure

Mitech MH600 catalog

Ulasan

Belum ada ulasan.

Hanya pelanggan yang sudah login dan telah membeli produk ini yang dapat memberikan ulasan.